Page 1 - Owner’s Manual

Data/Voice/Fax ConcentratorDesktop Models: DT101, DT102, DT101/xx, DT102/xxRack-Mount Models: DT101R, DT102R, DT101R/xx, DT102R/xxOwner’s Manual

Page 2 - DataTalker™ Series

10DataTalker Owner’s Manual1.3 Product DescriptionThe DataTalker series of multiplexers has a single synchronous or asynchronous data channel, acomman

Page 3 - Contents

100DataTalker Owner’s Manual7.6 Composite Link Settings - Internal ISDN TerminalAdapterTable 7-6. Composite Link Settings - Internal ISDN Terminal Ada

Page 4 - Chapter 7 - Troubleshooting

101Chapter 7 - Troubleshooting7.7 Composite Link Settings - Internal ModemTable 7-7. Composite Link Settings - Internal MMH2834Step Procedure1 Toggle

Page 5

102DataTalker Owner’s Manual7.8 Composite Link Settings - External DeviceTable 7-8. Composite Link Settings - External DeviceStep Procedure1 Toggle D

Page 6

103Chapter 7 - Troubleshooting7.9 Composite Link StatisticsTable 7-9. Composite Link StatisticsStep Procedure1 Toggle DIP switch position 3 to the do

Page 7

104DataTalker Owner’s Manual7 Comparing Data Blocks Transmitted with Data Blocks Retransmitted (the number ofretransmits needed to get the data throug

Page 8 - 1.2 About This Manual

105Chapter 7 - Troubleshooting7.10Data Port ConfigurationTable 7-10. Data Port ConfigurationStep Procedure1 Toggle DIP switch position 3 to the down

Page 9

106DataTalker Owner’s Manual7 If the data port is set up as an asynchronous data channel, you should verify all 12 options.Data Port Configuration1 -

Page 10 - 1.3 Product Description

107Chapter 7 - Troubleshooting7.11Voice/Fax Channel ConfigurationTable 7-11. Voice/Fax Channel ConfigurationStep Procedure1 Toggle DIP switch positio

Page 11

108DataTalker Owner’s ManualVoice/Fax Channel 1 Configuration1 - Destination Channel : 12 - Digitizing Rate : 96003 - Output Level

Page 12 - 1.4 System Features

109Chapter 7 - Troubleshooting7.12Diagnostic TestingTable 7-12. Diagnostic TestingStep Procedure1 Toggle DIP switch position 3 to the down (closed) p

Page 13 - 1.4.7 Operational Statistics

11Chapter 1 - Introduction and Descriptioncommunications software to the DATA/COMMAND connector on the back panel and configurethe data channel for th

Page 14

110DataTalker Owner’s Manual

Page 15

Chapter 8 - Warranty, Service and Tech Support

Page 16 - 1.7 Specifications

112DataTalker Owner’s Manual8.1 IntroductionThis chapter begins with your DataTalker’s 2-year warranty. Read carefully the next section,“Tech Support,

Page 17 - 1.7.8 Voice/Fax Channel

113Chapter 8 - Warranty, Service and Tech Support8.3 Tech SupportMulti-Tech has an excellent staff of technical support personnel available to help yo

Page 18 - 1.7.9 Electrical/Physical

114DataTalker Owner’s Manual8.4 The Multi-Tech BBSFor customers who do not have Internet access, Multi-Tech maintains a bulletin board system(BBS) tha

Page 19 - Chapter 2 - Configuration

115Chapter 8 - Warranty, Service and Tech Support6. Select a file transfer protocol by typing the indicated letter, such as Z for Zmodem (therecommend

Page 20 - 2.1 Introduction

116DataTalker Owner’s Manual

Page 22

118DataTalker Owner’s ManualAppendix A - ASCII Conversion ChartCTRL CODE HEX DEC CODE HEX DEC CODE HEX DEC CODE HEX DEC@ NUL 00 0 SP 20 32 @ 40 64 ` 6

Page 23

119Appendix B - RS-232C Interface SpecificationAppendix B - RS-232C Interface SpecificationThe DataTalker's RS232C interface circuits have been d

Page 24

12DataTalker Owner’s Manual1.4 System Features1.4.1 Voice/FaxThe voice/fax feature of the DataTalker allows you to establish voice or fax traffic on t

Page 25 - 101 MDM/TA

120DataTalker Owner’s ManualAppendix C - Cabling DiagramsChannel CablesDCE to Channel Cabling (with EIA pass-through)PIN NO.12345678202225123456782022

Page 26

121Appendix C - Cabling DiagramsComposite Link CablingPIN NO.123457815172025123457815172025ToExternalSynchronousModem/DSU/ Terminal AdapterConnectorCH

Page 27

122DataTalker Owner’s ManualRJ-48 Cable for Internal ISDN Terminal Adapter1 2 3 4 5 6 7 8TRRJ-48 Cable for Internal DSU1 2 3 4 5

Page 28 - Composite Link

123Appendix C - Cabling DiagramsE&M Voice/Fax Channel CableWhite-GreenGreen-WhiteWhite-OrangeWhite-BlueBlue-WhiteOrange-WhiteBrown-WhiteWhite-Brow

Page 29

124DataTalker Owner’s ManualAppendix D - Flow Control BackgroundFlow control refers to techniques used by computer devices and the DataTalker to stop

Page 30

125Appendix E - MMH2834 Modem S-RegistersAppendix E - MMH2834 Modem S-RegistersIntroductionThis section describes the MMH2834 memory locations called

Page 31

126DataTalker Owner’s ManualS11Tone Dialing: Tone Spacing and DurationUnit: 1 msRange: 1–255, 80–255*, 80–255***Default: 70, 80*, 80***Description: S1

Page 32 - Remote Site

127Appendix F - MMH2834 Modem CommandsAppendix F - MMH2834 Modem CommandsF.1 IntroductionBefore you can enter commands for the MMH2834 internal compos

Page 33

128DataTalker Owner’s ManualTYPE COMMAND DESCRIPTIONConfigure #L0 Negotiate V42 Mode During HandshakeError #L1 MNP On/LAPM OffCorrection #L2 LAPM On/M

Page 34

129Appendix F - MMH2834 Modem CommandsF.2 Dialing Action CommandsDial Command DThe letter D in a command causes the MMH2834 to dial the telephone numb

Page 35

13Chapter 1 - Introduction and Description1.4.6 DiagnosticsDiagnostics in a network are of considerable importance. That is why the DataTalker is equi

Page 36 - 3.2 Indicators

130DataTalker Owner’s ManualF.3 Dial Modifier CommandsPulse or Tone Dial P TThe MMH2834 dials numbers using either pulse or tone dialing, or a combina

Page 37

131Appendix F - MMH2834 Modem CommandsWait for New Dialtone WA W inserted in the dialing command causes the MMH2834 to wait for another dial tone, and

Page 38

132DataTalker Owner’s ManualF.4 Phone Number Memory CommandsStoring Phone Numbers D...NA telephone number and command line of up to sixty characters m

Page 39 - 3.3 Connectors

133Appendix F - MMH2834 Modem CommandsF.5 Configuration and Default Storage CommandsStore Configuration & S-Register Params. in Non-Volitile Memor

Page 40 - 3.3.9 MODEM LEASED Connector

134DataTalker Owner’s ManualF.6 Command Response (Result Code) CommandsEcho Command Mode Characters EIf the MMH2834 is connected to a full-duplex comp

Page 41 - 3.4 Switches and Shunts

135Appendix F - MMH2834 Modem CommandsTERSE VERBOSE0OK1 CONNECT2 RING3 NO CARRIER4 ERROR5* CONNECT 12006 NO DIALTONE7 BUSY8 NO ANSWER9* CONNECT 240011

Page 42 - 3.4.4 RS232C/V.35 Shunt

136DataTalker Owner’s ManualThe MMH2834 also can detect a distant busy signal, if after dialing, it reaches a busy number.This is useful because it al

Page 43

137Appendix F - MMH2834 Modem CommandsF.7 Phone Line Conditioning CommandsEnable or Disable Recognition of Remote Digital Loop Signal &TThe MMH283

Page 44 - 4.2 Unpacking

138DataTalker Owner’s ManualF.9 Error Correction CommandsYou can use AT commands to place your MMH2834 one of three V.42 (error correction) modes ofop

Page 45 - 4.3 Configuration Summary

139Appendix F - MMH2834 Modem CommandsEnable/Disable Auto-Reliable Fallback Character $FIn Auto-Reliable mode, the modem is given four seconds to esta

Page 46

14DataTalker Owner’s Manual1.5 FCC Regulations for Telephone Line Interconnection1. This equipment complies with Part 68 of the FCC rules. On the outs

Page 47

140DataTalker Owner’s ManualF.10Compression and Maximum Block Size CommandsData CompressionThe data compression (&E14) command enables data compre

Page 48 - 4.7 Configuration Procedure

141Appendix F - MMH2834 Modem CommandsF.11 Speed Conversion CommandsSpeed conversion is a necessary part of data compression since data must be presen

Page 49

142DataTalker Owner’s ManualSerial Port Baud Rate $SBThe $SB command presets the speed of the MMH2834's serial (RS232C) port, in both Originatean

Page 50 - Selection : _

143Appendix F - MMH2834 Modem CommandsF.12Immediate Action CommandsHelp Screens $HThe Help command is designed to give you short explanations on how

Page 51

144DataTalker Owner’s ManualListing On-Line Diagnostics L8The L8 command displays the current on-line CONNECT status status of the MMH2834. Thisdispl

Page 52

145GlossaryGlossaryAAC (Alternating Current): A power source whose signal crosses a reference voltage (usually called ground or zero). Alternatingbe

Page 53

146DataTalker Owner’s ManualBSC (Binary Synchronous Communications): Also called "bisync", this communications protocol was the first synch

Page 54

147GlossaryDe facto standards: A de facto standard is one of two types of voluntary standards recognized by a given market. It is introduced by asin

Page 55

148DataTalker Owner’s ManualFlow control: The process of regulating the speed at which data enters or leaves a serial port. Software flow control is

Page 56 - 5.2 Cabling

149GlossaryLLeased Line: A private, dedicated communications channel that connects two locations. This connection lasts for the duration of thesubsc

Page 57 - DIGITAL Connector

15Chapter 1 - Introduction and Description1.6 Canadian Limitations NoticeNotice: The Canadian Department of Communications label identifies certificat

Page 58 - Link Cable

150DataTalker Owner’s ManualPCMCIA (personal computer memory card international association): An organization of U.S. and Japanese companies set up t

Page 59 - FXO Connector

151GlossarySynchronous Transmission: The transmission of data which involves sending a group of characters in a packet. This is a commonmethod of tr

Page 60 - 5.3 V.35 Shunt

152DataTalker Owner’s ManualIndexSymbols2 or 4 Wire (E&M) option ...722 or 4 Wire option ...

Page 61 - 5.4 Power-On and Checkout

153IndexDialtone/Wink (E&M) option...72Digital data service (DDS) ...10Digital service

Page 62

154DataTalker Owner’s ManualRemote Interface Type option ...72REN...

Page 63

16DataTalker Owner’s Manual1.7 Specifications1.7.1 Async Data ChannelNumber of Channels OneMaximum Speed 115,200 bpsChannel Speed All standard speeds

Page 64

17Chapter 1 - Introduction and Description1.7.5 Internal ModemModulation ITU-T V.34; AT&T V.32 terbo; ITU-T V.32bis, V.32, V.22bis, V.22; Bell212A

Page 65

18DataTalker Owner’s Manual1.7.9 Electrical/PhysicalDesktop Models:Power Supply Input 100 to 250 VACPower Supply Output +5v@5A, +12v@1A, [email protected]

Page 66 - 6.2 Configurations Menu

Chapter 2 - Configuration

Page 67 - 6.2.1 Data Port Configuration

Owner’s Manual82052704 Revision EDataTalker™ SeriesDesktop Models: DT101, DT101/xx, DT102, DT102/xxRack-Mount Models: DT101R, DT101R/xx, DT102R, DT102

Page 68

20DataTalker Owner’s Manual2.1 IntroductionThe Multi-Tech DataTalker is available in both desktop (DT10x) and rack-mount (DT10xR)versions. The desktop

Page 69

21Chapter 2 - Configuration2.2 Configuration 1 - Dial-Up LinkConfiguration 1 is a dial-up link using a pair of DataTalkers to provide data communicati

Page 70

22DataTalker Owner’s ManualWhen you established communication, the Main Menu appeared. From the Main Menu you canconfigure the unit, display statistic

Page 71 - DataTalker

23Chapter 2 - ConfigurationEnter S and press ENTER to store all configurations for the main office.Set up the home office unit the same way, except th

Page 72

24DataTalker Owner’s ManualTo connect the home office DataTalker to its PC, connect an RS232C cable between the DATA/COMMAND connector on the DataTalk

Page 73

25Chapter 2 - Configuration2.3 Configuration 2 - MMH900 Series with Voice/FaxConfiguration 2 adds voice capability to an existing data-only network us

Page 74 - P - Previous Menu

26DataTalker Owner’s ManualA series of configuration menus provides simple and complete configuration information for eachaspect of the DataTalker. Fr

Page 75

27Chapter 2 - ConfigurationThe data port in this configuration will be set up for synchronous operation. To configure the dataport for sync operation

Page 76

28DataTalker Owner’s Manual2.4 Configuration 3 - LAN to LANConfiguration 3 is an example of a pair of DataTalkers providing the link between two LANs

Page 77

29Chapter 2 - ConfigurationTo configure the DataTalker, enter 1 and press ENTER.The Configurations menu is displayed. From this menu you can configure

Page 78 - 6.3 Statistics

ContentsChapter 1 - Introduction and Description1.1 Introduction...

Page 79 - 6.5 Diagnostic Tests

30DataTalker Owner’s ManualData Port Configuration1 - Async/Sync: Sync 2 - Speed: 192003 - Clocking: Internal4

Page 80 - 6.5.1 Loop Tests

31Chapter 2 - ConfigurationThe DataTalker knows the type of link device being used by the way a DIP switch is set or bydetecting a device installed on

Page 81 - 6.6 Configure Remote Unit

32DataTalker Owner’s Manual2.5 Configuration 4 - PBX to PBXConfiguration 4 is a data/voice/fax configuration that uses two DataTalkers to link two PBX

Page 82 - 6.6.2 Quick Setup

33Chapter 2 - ConfigurationThe Configurations menu is displayed. From this menu you can configure the data port, voice/faxchannel(s), or the composite

Page 83 - RJ11 Phone

34DataTalker Owner’s ManualComposite Link Settings - Internal TA1 - On-Line XMT Rate: 128000 2 - Configure TA3 - DOD/DOI:

Page 84 - RS232 Cable

Chapter 3 - Front and Rear Panel Descriptions

Page 85

36DataTalker Owner’s Manual3.1 IntroductionThis chapter describes the DataTalker front and back panels and switches. The front panelcontains LED indic

Page 86

37Chapter 3 - Front and Rear Panel DescriptionsVoice/Fax ChannelsFXS (Foreign Exchange Station) This indicator lights when the voice/fax channel is co

Page 87

38DataTalker Owner’s Manual28.8/56 (28.8K bps/56K bps) This composite link speed indicator displays the baud rate of theinternal modem (28.8) or DSU (

Page 88 - 7.1 Introduction

39Chapter 3 - Front and Rear Panel Descriptions3.3 ConnectorsThe cable connections for the DataTalker are made at the back panel. Refer to Chapter 5 f

Page 89 - 7.3 Test Cables

Chapter 4 - Unpacking and Configuration4.1 Introduction...

Page 90 - 7.4 Troubleshooting Guide

40DataTalker Owner’s Manual3.3.7 VOICE/FAX CHANNEL 1 E&M ConnectorUse the E&M connector to connect the DataTalker to the E&M connector on

Page 91

41Chapter 3 - Front and Rear Panel Descriptions3.4 Switches and ShuntsDataTalker switches include one or two switches on the front panel, a power swit

Page 92

42DataTalker Owner’s Manual3.4.3 DIP SwitchThe eight-position DIP switch is accessible through a cutout in the left side of the DataTalkerseries enclo

Page 93

Chapter 4 - Unpacking and Configuration

Page 94 - Internal MMH2834 Modem

44DataTalker Owner’s Manual4.1 IntroductionThis chapter describes what to expect in your DataTalker shipping box, then describes how toconfigure the D

Page 95

45Chapter 4 - Unpacking and Configuration4.3 Configuration SummaryThe following chart shows possible configurations for your DataTalker. Use it as a s

Page 96 - Sync Data Channel

46DataTalker Owner’s Manual4.5 Voice/Fax Channel Configuration ConsiderationsWhen configuring the voice/fax channels on your DataTalker, the first que

Page 97

47Chapter 4 - Unpacking and Configuration4.6 Composite Link Configuration ConsiderationsThe composite link configuration depends on the type of device

Page 98

48DataTalker Owner’s Manual4.7 Configuration ProcedureTable 4-1. Configuration ProcedureStep Procedure1 Review the configuration considerations for th

Page 99

49Chapter 4 - Unpacking and Configuration6 Apply power to the terminal or PC. Run your PC communications software in terminal mode.Press the ENTER key

Page 100

AppendixesAppendix A - ASCII Conversion Chart ...118

Page 101

50DataTalker Owner’s Manual9 Configure the data port to meet the conditions of your installation by selecting optionnumbers from the menus. Refer to C

Page 102

51Chapter 4 - Unpacking and Configuration12 Configure voice/fax channel 1 to meet the conditions of your installation by selecting optionnumbers from

Page 103 - 7.9 Composite Link Statistics

52DataTalker Owner’s Manual• Configure the internal MMH2834 modem to meet the conditions of your installation byselecting option numbers from the menu

Page 104

53Chapter 4 - Unpacking and ConfigurationTo verify and/or change the terminal adapter’s configuration, select option 2, wait 5 seconds,and enter AT!V

Page 105 - 7.10Data Port Configuration

54DataTalker Owner’s Manual

Page 106

Chapter 5 - Installation

Page 107

56DataTalker Owner’s Manual5.1 IntroductionThis chapter describes how to connect the DataTalker to your system (Table 5-1) and how tomove the RS232/V.

Page 108

57Chapter 5 - InstallationMMH2834 Modem, Leased LineConnect the RJ-11 phone cable supplied with the DataTalker from the internal modemLEASED connector

Page 109 - 7.12Diagnostic Testing

58DataTalker Owner’s ManualExternal Modem, DSU, or ISDN Terminal Adapter3 If the external device has an RS232 interface, connect the composite link ca

Page 110 - DataTalker Owner’s Manual

59Chapter 5 - InstallationIf you are connecting the voice/fax channel to the station side of a PBX, connect an RJ-11phone cable from the VOICE/FAX CHA

Page 112 - 8.2 Limited Warranty

60DataTalker Owner’s Manual5.3 V.35 ShuntTable 5-2. V.35 Shunt ProcedureStep Procedure1 Desktop version: Unplug the power supply from the back of the

Page 113 - 8.3 Tech Support

61Chapter 5 - Installation5.4 Power-On and CheckoutThe desktop and rack-mounted versions of the DataTalker differ in how power is applied. Thedesktop

Page 114 - 8.4 The Multi-Tech BBS

62DataTalker Owner’s Manual6 Verify that the voice/fax channel is connected at the remote site. One of the followingconditions will apply depending on

Page 115 - 8.5 About the Internet

63Chapter 5 - InstallationVoice/Fax ChannelIf the voice/fax channel is not communicating with the remote site or the remote site cannotcommunicate wit

Page 116

64DataTalker Owner’s Manual

Page 117 - Appendixes

Chapter 6 - Menus

Page 118

66DataTalker Owner’s Manual6.1 IntroductionThe menu system for the DataTalker provides a set of user-friendly configuration menus that areaccessible f

Page 119

67Chapter 6 - Menus6.2.1 Data Port ConfigurationThe Data Port Configuration menu allows you to configure the data channel for eitherasynchronous or sy

Page 120 - Appendix C - Cabling Diagrams

68DataTalker Owner’s ManualThe Echo option enables data entered on the channel device keyboard to be returned to thechannel device monitor. The purpo

Page 121 - Composite Link Cabling

69Chapter 6 - Menus6.2.2 Sync Data Port ConfigurationThe Data Port Configuration menu allows you to configure the data channel for eitherasynchronous

Page 122

Chapter 1 - Introduction and Description

Page 123 - DSU Back-to-Back Cable

70DataTalker Owner’s Manual6.2.3 Voice/Fax Channel ConfigurationThe Voice/Fax Channel Configuration menu is displayed only if the second voice/fax cha

Page 124 - DATA DATA

71Chapter 6 - MenusThe output level attentuation needs to be set at the DataTalker that is receiving (hearing).Increasing the output level gain at the

Page 125

72DataTalker Owner’s ManualThe Local Interface Type option configures the local voice/fax channel interface. The optionsare for an FXS, FXO, or E&

Page 126

73Chapter 6 - Menus6.2.4 Composite Link ConfigurationThe Composite Link Configuration menu that is displayed depends on whether an internal orexternal

Page 127 - F.1 Introduction

74DataTalker Owner’s ManualThe Dial/Leased option selects the type of connection to the telephone company. If the data lineprovided by the telephone c

Page 128

75Chapter 6 - MenusComposite Link Settings - Internal 56K DSUThe Composite Link Settings - Internal DSU menu allows you to configure the composite lin

Page 129 - F.2 Dialing Action Commands

76DataTalker Owner’s ManualThe Dial On Demand (DOD)/Disconnect On Inactivity (DOI) option drops DTR to the terminaladapter to disconnect if the inacti

Page 130 - F.3 Dial Modifier Commands

77Chapter 6 - MenusComposite Link Settings - External DeviceThe Composite Link Settings - External Device menu allows you to configure the composite l

Page 131 - Quiet Answer @

78DataTalker Owner’s Manual6.3 StatisticsThe Statistics menu allows you display or clear the composite link statistics, or return to theprevious menu

Page 132 - Number Linking N...N

79Chapter 6 - Menus6.4 Reset OptionsThe Reset Options menu allows you to reset the unit, the data and voice/fax channels, eachvoice/fax channel, or ju

Page 133 - Modem Reset Z

8DataTalker Owner’s Manual1.1 IntroductionCongratulations! Your new Multi-Tech DataTalker™ is one of the finest data/voice/faxconcentrators on the mar

Page 134

80DataTalker Owner’s Manual6.5.1 Loop TestsThe Loop Tests menu provides either a voice loopback or a composite link loopback thatdepends on the type o

Page 135

81Chapter 6 - Menus6.6 Configure Remote UnitConfiguration menu option 5 is dependent on the position of DIP switch SW-5. If DIP switch SW-5 is in the

Page 136

82DataTalker Owner’s ManualThe Unit Source Node option specifies the node number of the local node. This number has tobe unique and any number from 0

Page 137

83Chapter 6 - MenusTable 6-1. Main Office InstallationStep Procedure1 Voice/Fax - Plug an analog PBX extension into the FXO jack on the back of the D

Page 138 - F.9 Error Correction Commands

84DataTalker Owner’s Manual3 Data Port - Plug the host computer into the Data/Command port and put dip switch 3 up(located on the side of the Data Tal

Page 139 - Retransmit Count $R

85Chapter 6 - MenusTable 6-2. Home Office InstallationStep Procedure1 Voice/Fax - Plug your telephone into the FXS jack on the back of the Data Talke

Page 140 - Maximum Block Size &BS

86DataTalker Owner’s Manual3 Data Port - Plug your PC into the Data/Command port and put dip switch 3 up to exitcommand mode and enable data mode (loc

Page 141 - Modem Baud Rate $MB

Chapter 7 - Troubleshooting

Page 142 - Serial Port Baud Rate $SB

88DataTalker Owner’s Manual7.1 IntroductionThe DataTalker is designed to be easy to operate and maintain. The procedures in this chapterwill help isol

Page 143 - F.12Immediate Action Commands

89Chapter 7 - Troubleshooting7.3 Test CablesIf you are using the DataTalker internal DSU or MMH2834 modem, there are three test cablesyou can use to c

Page 144

9Chapter 1 - Introduction and DescriptionChapter 4 - Unpacking and ConfigurationThis chapter describes the contents of the shipping container; provide

Page 145 - Glossary

90DataTalker Owner’s Manual7.4 Troubleshooting GuideThis troubleshooting guide is designed to help you pinpoint the cause of your problem andcorrect i

Page 146

91Chapter 7 - TroubleshootingTable 7-1. Command Port TroubleshootingProblemCommand port device notcommunication with DataTalkerPossible CausesCommunic

Page 147

DataTalker Owner’s Manual92Table 7-2. Composite Link Troubleshooting Internal DSUProblemComposite link down with CD,CTS, XMT, RD and RCV LEDsonFlashin

Page 148

93Chapter 7 - TroubleshootingInternal ISDN Terminal AdapterProblemComposite link down with CTS,XMT and RD LEDs onComposite link down with CD,CTS, XMT,

Page 149

DataTalker Owner’s Manual94Internal MMH2834 ModemProblemComposite link down with CTS,XMT, and RD LEDs onComposite link down with CD,CTS, XMT, RCV and

Page 150

95Chapter 7 - TroubleshootingExternal Composite Link DeviceProblemComposite link down with CTS,XMT and RD LEDs onComposite link down with CD,CTS, XMT,

Page 151

DataTalker Owner’s Manual96Table 7-3 Data Channel TroubleshootingProblemAsync Data ChannelChannel Device notcommunicating with DataTalker;composite li

Page 152

97Chapter 7 - TroubleshootingTable 7-4. Voice/Fax TroubleshootingProblemVolume levels not sufficient onlocal voice/fax channelLocal telephone goes off

Page 153

DataTalker Owner’s Manual98Table 7-4. Voice/Fax Troubleshooting (continued)ProblemVoice conversation or fax trafficbecomes erratic after changingthe r

Page 154

99Chapter 7 - Troubleshooting7.5 Composite Link Settings - Internal DSUTable 7-5. Composite Link Settings - Internal DSUStep Procedure1 Toggle DIP swi