Chapter 4 - Commands
VALUES: n = 0, 1, 2 or 4
DEFAULT: &C1
DESCRIPTION: &C0 forces Carrier Detect on.
&C1 lets Carrier Detect act normally.
&C2 lets Carrier Detect drop S24 time on disconnect.
&C4 resets modem when Carrier Detect drops.
COMMAND: &CDn
VALUES: n = 0 or 1
DEFAULT: &CD0
DESCRIPTION: &CD0 execute cleardown on disconnect.
&CD1 do not execute cleardown on disconnect.
COMMAND: Ds
VALUES: s = phone #
DEFAULT: n/a
DESCRIPTION: Dial a telephone number “s”, where s may include up to 60
digits or T, P, R, comma and ; characters.
COMMAND: DsNd
VALUES: s = phone # and d = 0 thru 9
DEFAULT: n/a
DESCRIPTION: Store telephone number. To store, enter phone number "s",
followed by N, then Directory Number "d".
COMMAND: &Dn
VALUES: n = 0 thru 3
DEFAULT: &D2
DESCRIPTION: &D0 means DTR is ignored
&D1 means modem returns to command mode.
&D2 lets modem react to DTR normally.
&D3 resets the modem to default parameters.
COMMAND: $Dn
VALUES: n = 0 or 1
DEFAULT: $D0
DESCRIPTION: $D0 disables DTR Dialing.
$D1 enables DTR Dialing.
COMMAND: %DF
VALUES: n = 0 or 1
DEFAULT: %DF0
DESCRIPTION: %DF0 selects V.34 Line Probe Data in Graph Format.
%DF1 selects V.34 Line Probe Data in Table Format.
COMMAND: %DP