Chapter 3 – Using the Web Management Software
Multi-Tech Systems, Inc. MultiModem Wireless Modem with Ethernet Interface (S000375A) 21
PPP
PPP > PPP Configuration
PPP General
PPP Enable/disable PPP. Default is Enable.
Dial-on-Demand: Enable/disable Dial-on-Demand. Default is Enable. If you disable it, the modem will
always stay connected.
Idle Time Out: Set the amount of idle time that will pass before the modem will timeout. Default is
180 seconds.
Connect Time Out: Set the amount of seconds to wait for a connection while in receive mode before
timing out.
Dialing Max Retries: Enter the number of dialing retries allowed. Default is zero, which means an infinite
number is allowed. Range 0 to 100.
Authentication
Authentication Type: Set the authentication protocol type that will negotiate with the remote peer:
pap/chap/pap-chap. Default is pap-chap.
User Name: Enter the User Name with which the remote peer will authenticate. Default is
ipmodule.
Password: Enter the Password with which the remote peer will authenticate. Default is ipmodule.