Chapter 3 – Fax Class 2 Commands
Multi-Tech Systems, Inc. SocketModem MT5634SMIxx Reference Guide (S000263C) 81
Addressing & Polling Frames
Class 2.1 +FSA, +FPA, +FPW
Write syntax: +FSA="<destination Subaddress string>"
+FPA="<selective Polling Address string>"
+FPW="<Password string>"
Values: 20 digit numeric ASCII string: digits 0-9, *, # and space only
Default: Null String
The modem sends the numeric string contained in +FSA, +FPA or +FPW at the times
specified in Recommendation T.30, if the corresponding parameter is not a Null
String. The +FPW parameter is used for the PWD frame sent with either DTC or with
DCS.
The +FSA=?, +FPA=?, and +FPW=? test commands report the corresponding
ranges of character values supported.
The modem transmits digit string characters to the remote station in reversed time
order from the order in the command line. If less than 20 characters are specified in a
non-Null String, the modem appends space characters. If the specified string is more
than 20 characters in length, an ERROR result code is generated.
Class 2 There are no equivalent parameters in Class 2.