Multi-tech-systems MT3334ZDX Manuel d'utilisateur Page 55

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 71
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 54
Appendices
55
Interface
EIA RS232C/CCITT V.24
Connectors
DB25 (
RS232C
) connector; Two RJ11
modular phone jack: for line, and
telephone set, power jack.
Diagnostics
Power-on Self Test, Local Analog Loop,
Local Digital Loop, Remote Digital Loop.
Indicators
LEDs for Send Data, Receive Data,
Carrier Detect, various speed indicators,
Off Hook, Terminal Ready, Error
Correction, Fax.
Controls
Power ON/OFF Switch
Speaker
Speaker with software- or command-
controlled volume.
Operating
0° to 50° C
Temperature
Power Requirement
115 Volts AC, 60 Hz, .3 amp (2-prong
outlet-mounted transformer); 240V/50Hz
optional (international)
Power Consumption
5 Watts
Dimensions
14.8 x 10.8 x 2.9 cm (L x W x D)
Weight
224 grams
Limited Warranty
Five years